← Back

Spectroscopic Characterization, Thermogravimetry and Biological Studies of Ru(III), Pt(IV), Au(III) Complexes with Sulfamethoxazole Drug Ligand

POWER ANALYZER 3390-10 Power measuring instruments Maximizing the Efficiency of Energy Conversion Super Precise ±0.1% Accuracy Model to Meet the Demanding Needs of Today Exceed the Accuracy of Direct Wiring With Pull-Through Current Sensors Pull-through Current Sensors Models CT6862-10, CT6863-10 and 9709-10 For 50A, 200A and 500A Testing Find Quality Products Online at: www. GlobalTestSupply.com sales@GlobalTestSupply.com 2 A Higher-Accuracy Power Meter Supporting the Attainment of Maximum Efficiency T he needs of electrical devices driving energy conservation and green energy initiatives such as motors, inverters, solar panels, power conditioners, electric vehicles, and air conditioners are increasing at a pace never seen before. For R&D centers wishing for 0.1% levels of efficiency improvement, highly precise and accurate large current measurements are now within reach. The new 3390-10 delivers unsurpassed top-of-the-class ±0.1% accuracy to aid in accomplishing maximum efficiency in all of your devices. Improved Efficiency POINT Enhanced Accuracy Larger Currents the 3390-10 with High Accuracy Sensors 1 Pair And Achieve an Even Higher Level of Excellence in Testing High Accuracy Version of Model 3390 High Accuracy Versions of Pull-through Current Sensors Enriched Current Sensors Offer Even High Accuracy Pull-through Current Sensor Pull-through Current Sensor CT6862-10 50A CT6863-10 200A 3390-10 CT686x-10 series 9709-10 0.1% Combined Accuracy of 0.16% ± Standard 3390 Accuracy Pull-through Current Sensor 9709-10 500A Pull-through current sensors deliver accuracy surpassing that of traditional shunt resistors while remaining resilient against overheating to enable high current measurements ± Standard Setup Power Meter Accuracy Current Sensor Accuracy High Accuracy Setup ±0.1% Combined ±0.06% Defined Combined Accuracy All Ranges Accuracy differs depending on current range 45 to 66Hz 45 to 66Hz ±0.1% ±0.16% Refer to specifications for DC accuracy. Enhanced accuracy parameters available with the higher accuracy combination: •Voltage Measurement Accuracy: DC (45 to 66 Hz accuracy remains the same as the 3390) •Current and Active Power Measurement Accuracy: DC and 45 to 66Hz •Effect of Power Factor: 45 to 66Hz Accuracy for other parameters is the same as that on the standard Model 3390. Accuracy is guaranteed for 1 year. GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com Accuracy for the high accuracy Models 3390-10 and Current Sensors are not defined individually. Please use these products in combination to obtain ±0.1% accuracy. No need to worry about setting the correct range. POINT 3 on ALL Ranges 2 ±0.1% Switch from one range to another and still maintain the same accuracy. 500A Sensor 500A Range 50A Range 10A Range High Accuracy Model 3390-10 Accuracy(%) Accuracy(%) Standard Model 3390 ±0.65% Accuracy depends on the range ±0.5 ±0.16% 0.0 ±0.5 ±0.25% 500A Range 50A Range 0.0 10A Range Accuracy when pairing Model 3390 with the 9709 AC/DC Current Sensor (500A) and measuring the f.s. current at each range Accuracy is ±0.1% at ANY range ±0.1% ±0.1% ±0.1% 500A Range 50A Range 10A Range Accuracy when pairing Model 3390-10 with the 9709-10 AC/DC Current Sensor (500A) and measuring the f.s. current at each range (45 to 66Hz) (45 to 66Hz) High Accuracy Guarantee Period is Further Extended POINT guaranteed for 1 year 3 Accuracy Minimize calibration frequency and maximize work efficiency Standard Model 3390 ▼ 3390-10 6 months* 12 months High Accuracy Model The following options are also offered with 1 year guaranteed accuracy: MOTOR TESTING OPTION 9791 D/A OUTPUT OPTION 9792 MOTOR TESTING & D/A OUTPUT OPTION 9793 Find Quality Products Online at: www. For 1-year guaranteed accuracy on Model 3390, the accuracy uncertainty must increase 1.5 times the accuracy guaranteed for 6 months. GlobalTestSupply.com *Accuracy for Models 9791, 9792 and 9793 remain the same. sales@GlobalTestSupply.com POINT on Any Channel 4 Measure High accuracy using HIOKI high accuracy current sensors is guaranteed, no matter which channel you use 200A Sensor 500A Sensor Conditions for Current Input Guaranteed Accuracy Model 3390-10 Specifications A c c u r a c y Accuracy guaranteed for 1 year DC 45Hz to 66Hz Only when using HIOKI high-accuracy current sensors (options) (Accuracy specifications defined for Model 3390 apply when other sensors are used) Temperature and 23°C±3°C(73°F±5°F), max. 80% rh (3390-10) Humidity Range 23°C±5°C(73°F±9°F), max. 80% rh (when using the 50A to 500A range of Model 9709-10) ±1°C(1.8°F) of temperature after zero adjustment, within 23°C±5°C(73°F±9°F), max. 80% rh (when using the 10A and 20A range of Model 9709-10) 0 to 40°C(32°F to 104°F), max. 80% rh (when using Model CT6862-10 or CT6863-10) Warm-up time At least 30 minutes Voltage(U) Current(I) Active Power(P) ±0.07%rdg.±0.1%f.s. ±0.07%rdg.±0.1%f.s. ±0.07%rdg.±0.1%f.s. ±0.05%rdg.±0.05%f.s. ±0.05%rdg.±0.05%f.s. ±0.05%rdg.±0.05%f.s. Accuracy is defined for the frequency range indicated above only when pairing Model 3390-10 with HIOKI high accuracy current sensors (where f.s. is based on the ranges of the 3390-10). Voltage and active power values for 1000V or higher measurements are for reference only. On condition that the signal is a sine wave, with power factor=1, voltage to ground=0V, after zeroadjustment is conducted with current sensors at 0.5Hz to 30Hz ±0.1%rdg.±0.2%f.s. ±0.1%rdg.±0.2%f.s. ±0.1%rdg.±0.2%f.s. 23°C±3°C(73°F±5°F), and when the fundamental 30Hz to 45Hz ±0.1%rdg.±0.1%f.s. ±0.1%rdg.±0.1%f.s. ±0.1%rdg.±0.1%f.s. waveform is the sync source 66Hz to 1kHz ±0.1%rdg.±0.1%f.s. ±0.1%rdg.±0.1%f.s. ±0.1%rdg.±0.1%f.s. Temperature When used within the operating temperature range but outside the guaranteed 1kHz to 10kHz ±0.2%rdg.±0.1%f.s. ±0.2%rdg.±0.1%f.s. ±0.2%rdg.±0.1%f.s. c o e f f i c i e n t temperature and humidity ranges for accuracy, add the following (the f.s. of the ranges of Model 3390-10 applies) 10kHz to 50kHz ±0.3%rdg.±0.2%f.s. ±0.3%rdg.±0.2%f.s. ±0.4%rdg.±0.3%f.s. 3390-10 ±0.01%f.s./°C; for DC, add ±0.01%f.s./°C 50kHz to 100kHz ±1.0%rdg.±0.3%f.s. ±1.0%rdg.±0.3%f.s. ±1.5%rdg.±0.5%f.s. 9709-10 Current: ±0.01%rdg./°C; for DC, add ±(0.005%f. ±20%f.s. ±20%f.s. ±20%f.s. 100kHz to 150kHz s.+2mA)/°C Active power: ±0.01%rdg./°C; for DC, add ±(displayed For current and active power accuracy within the frequency range indicated above, voltage value x (0.005%f.s.+2mA))/°C add the uncertainty range of the current sensors. The following accuracy data are for reference only: CT6862-10, Current: ±0.01%rdg./°C; for DC, add ±0.005%f.s. /°C Voltage, current and active power within the 0.5Hz to 10Hz frequency range CT6863-10 Active Power: ±0.01 Voltage and active power exceeding 220V within the 10Hz to 10Hz frequency range E f f e c t o f Maximum ±0.2%f.s. (at 45Hz to 66Hz, p.f.=0.0) Voltage and active power exceeding 750V within the 30kHz to 100kHz frequency range Voltage and active power exceeding (22000/f[kHz])V within the 100kHz to 150kHz frequency range Power Factor Add ±0.45%f.s. when LPF is 500 Hz Voltage(U) Current(I) Input Active Power(P) Voltage and active power exceeding 1000V For specifications not defined above, please refer to the catalog for Model 3390 Power Analyzer. Power Analyzer (High Accuracy Model) 3390-10 Dedicated Current Sensors (High Accuracy Models) AC/DC CURRENT SENSOR(50A) CT6862-10 AC/DC CURRENT SENSOR(200A) CT6863-10 AC/DC CURRENT SENSOR(500A) 9709-10 Supplied Accessories: Instruction Manual for Model 3390 x 1, Instruction Manual for Model 3390-10 x 1, Measurement Guide x 1, Power cord x 1, USB cable x 1, D-sub connector x 1 (when 9792 or 9793 is installed), Color label x 2 Please note: The dedicated PC application software and communication command manual for Model 3390 are also compatible to Model 3390-10. Please download them from the HIOKI website. Please purchase separately-sold voltage cords and current sensors for measurements. A HIOKI-issued PC card is also necessary in order to save measured data. If calibration data sheets pairing the 3390-10 with specific current sensors are required, please specify at time of order. Calibration data sheets for specific combinations after the products have been delivered will require that the devices be returned to the HIOKI factory for re-calibration. Please also specify preferred channels if necessary. Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies. HIOKI (Shanghai) SALES & TRADING CO., LTD.: TEL +86-21-63910090 FAX +86-21-63910360 http://www.hioki.cn / E-mail: info@hioki.com.cn DISTRIBUTED BY HIOKI INDIA PRIVATE LIMITED: TEL +91-124-6590210 FAX +91-124-6460113 HEADQUARTERS: E-mail: hioki@hioki.in 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 FAX +81-268-28-0568 HIOKI SINGAPORE PTE. LTD.: http://www.hioki.com / E-mail: os-com@hioki.co.jp TEL +65-6634-7677 FAX +65-6634-7477 E-mail: info@hioki.com.sg Find Quality Products Online at: www. GlobalTestSupply.com HIOKI USA CORPORATION: HIOKI KOREA CO., LTD.: TEL +1-609-409-9109 FAX +1-609-409-9108 TEL +82-42-936-1281 FAX +82-42-936-1284 http://www.hiokiusa.com / E-mail: hioki@hiokiusa.com E-mail: info-kr@hioki.co.jp All information correct as of Jun. 18, 2013. All specifications are subject to change without notice. sales@GlobalTestSupply.com 3390-10E2-36M Printed in Japan